FRONTIER X2 FOR REMOTE CARDIAC CARE

Until now, monitoring your patient’s cardiac status at home or during exercise required complex devices, chest preparation, patches, wires, and a physical visit to the hospital to get their data analyzed.

Frontier X2 continuously monitors your patient's cardiac and respiratory health and provides them with real- time feedback with on-board vibration alerts and as well as a way for you to access their ECG, vitals and activity remotely.

APPLICATIONS OF THE FRONTIER X2

FRONTIER X2 FOR CARDIAC REHABILITATION

  • Remotely monitor ECG, Heart Rate, Breathing Rate, ST-segment changes and Activity in real-time.
  • Centralised Multi-user Monitoring Dashboard.
  • Activity History to monitor compliance.
  • Set Vibration Alerts according to exercise prescription.
  • Assess fitness remotely by monitoring 6 Minute Walk Test or Step Test.

FRONTIER X2 FOR PROLONGED AMBULATORY ECG MONITORING, ARRHYTHMIA DETECTION AND ATRIAL FIBRILLATION

  • Enhanced Patient Comfort with lightweight wireless device.
  • Continuous Recording for over 24 hours with 1 hour recharge time.
  • AI-powered Arrhythmia Detection for rapid analysis of long recordings.
  • Rate Control and Arrhythmia Burden detection.
  • Event Marker and Notes for symptoms.
  • Monitor response to Anti-arrhythmic Drugs and QTc Prolongation.

FRONTIER X2 FOR REMOTE MONITORING AND TELE-CONSULTATIONS

  • Remotely monitor ECG and Vitals.
  • Centralised Multi-user Monitoring Dashboard.
  • Vibration alerts for increased Respiratory Rate and ST-segment Depression.
  • Contactless Monitoring for step-down facilities.
  • Easy to Disinfect.

FRONTIER X2 FEATURES

Live Stream ECG

Instantly

With a comfortable, easy to wear chest strap, remotely live stream your patient's ECG to any web browser or mobile device across the world.

Automated analysis.

Rhythm, ST changes & more

Analyse long recordings easily with AI powered detection of arrhythmias, analysis of ST- segment changes and visualisation of conduction intervals.

Don't miss early signs.

Real-time vibration alerts

Get informed as soon as a patient crosses their set thresholds for ST segment change, breathing rate, heart rate or develops arrhythmias.

Context is everything.

Event markers and activity

Understand relationships between patient activity, drug dose and timings; and changes in arrhythmia burden.

Continuous Monitoring.

Round the clock care.

Monitor multiple patients simultaneously from the comfort of your home. Continuous updates of real-time vitals of your patients or loved ones.

Visualise trends.

Predict patient needs.

Summary trend lines of select vitals can support early clinical decision making. Pre-empt an emergency

Understand Exercise.

Improve Outcomes

Objective data on your patient's compliance to ambulation, rehabilitation or lifestyle modification. Information on activity, intensity and duration with ECG recorded throughout

EXPLORING THE DASHBOARD

Sample Reports

CASE REPORTS

Frontier X2 identified symptomatic paroxysmal Atrial fibrillation. A 94 year old male with known coronary artery disease, hypertension post PCI presented with new onset palpitation. He recorded a 24 hour recording in which the Frontier X2 AI arrhythmia detection algorithm delineated sections of paroxysmal atrial fibrillation which coincided with periods of the reported symptoms.

Frontier X2 report was reviewed by a cardiac electrophysiologist and the patient was advised overnight telemetry monitoring confirming Frontier X2 findings and patient was prescribed a low dose beta-blocker for symptomatic Ventricular arrhythmia.

Validation

The accuracy of the vital parameters measured by the Frontier X2 has been validated by testing against the standard of care devices for each of the following parameters:

Frontier X2

SEER1000 Holter Monitor

Arrhythmia Classification

Simultaneous recordings of Frontier X2 and a 12 Lead ECG Stress test are attached, which demonstrate that the ECG acquired on Frontier X2 closely resembles the morphology of the ECG acquired on Lead V5 of the 12-Lead ECG and that all arrhythmias identifiable on Leads II and V5 of the 12-Lead ECG can also be identified on the ECG recorded on the Frontier X2.

Heart Rate

Performance of the Frontier X2 measurements of heart rate was evaluated in a sample of nineteen healthy volunteers, comparing RRI (R-R Interval) measurements by the Frontier X2 against RRI obtained from a single lead on the GE SEER 1000 Holter monitor resulted in a mean error of 0.04±1.5 (ms) and a mean absolute error of 1.10±1.11 (ms).

Breathing Rate

Performance of the Frontier X2 measurements of breathing rate was evaluated in a sample of nineteen healthy volunteers, by comparing average breathing rate measurements by the Frontier X2 against 20 second average of breath-to breath measurements of respiratory rate obtained from the Cortex Metalyzer 3B CPET device resulted in a mean error of 3.03±1.43 (breaths per minute).

ST-Segment Deviation

Performance of the Frontier X2 measurements of ST-segment was evaluated in a sample of nineteen healthy volunteers, by comparing ST-segment measurements by the Frontier X2 against RRI obtained from a Lead CC5 on the GE SEER 1000 Holter monitor. This comparison study resulted in a mean error of 0.031 ±0.043 (mV) with a mean absolute error of 0.041 ±0.033 (mV).

Corrected QT Interval

Performance of the Frontier X2 measurements of QTc interval was evaluated in a sample of twenty-two healthy volunteers, by comparing QTc measurements by the Frontier X2 against a 3-Lead GE SEER 1000 Holter Monitor. This resulted in an error of 12.17 ± 8.25 (ms) compared to Lead 1, 11.78 ± 7.56 (ms) compared to Lead CM5, and 10.8 ± 7.69 (ms) compared to Lead CC5. Pearson's correlation coefficients for the Frontier X2 in relation to Leads 1, CM5 and CC5 were 0.84, 0.89 and 0.92 respectively .

TESTING AND STANDARDS

Device:

  • Compliant with the following standards- FCC (US), IC (Canada), CE(Europe) , WPC ETA (India), WEEE
  • Compliant with IP67 water resistance standards
  • Compliant with environmental/safety/ reliability standards- IEC60068-2-1, IEC60068-2-2,IEC60068-2-6, IEC60068-2-14, IEC60068-2-78, IEC61010-1, IEC60529

Chest Strap:

  • Compliant with REACH and RoHS2 standards